Now with the removal of U-500 vials from the market, what is the current guidance, safety literature, and standard of care for U-500 insulin use in the pumps? Is it safe to use a U-500 pen to refill a pump?

Comment by InpharmD Researcher

Use of U-500 pens to refill an insulin pump does not appear to be broadly supported, with exception of a single case report in which the patient was directed to withdraw U-500 from pens using pod-filling syringes. However, the product’s prescribing information specifically instructs to not use Humulin R U-500 in an insulin pump. Based on the current lack of evidence, such use cannot be concluded to be safe or widely acceptable.

A literature search was conducted using PubMed and Google Scholar to identify current guidance and published evidence regarding U-500 insulin use in insulin pumps, with emphasis on the safety of transferring insulin from pens into pump reservoirs.

Background

Evidence regarding the safety of transferring U-500 insulin from pens into insulin pumps appears limited to a single recently published 2026 case report involving a 46-year-old man with type 1 diabetes and severe insulin resistance using U-500 insulin in an Omnipod 5 automated insulin delivery system (see Table 1). Following discontinuation of U-500 vials in France in February 2026, the patient received training to withdraw insulin from pens using syringes supplied with the pump kits. Over 12 months following initiation of automated insulin delivery, time in range increased from 75% to 79.1%, while time below range decreased from 9% to 5.7%, with no severe hypoglycemia, diabetic ketoacidosis, or recurrent technical issues suggestive of insulin incompatibility. However, these outcomes reflect the overall transition to automated insulin delivery rather than pen-to-pump transfer specifically, as the duration of follow-up after switching to pen-derived insulin was not reported. Although the case documents the feasibility of this off-label approach, it does not establish the safety of transferring U-500 insulin from pens into pumps, particularly given the single-patient design and lack of a separate safety assessment following the switch. [1]

Background References: [1] Dreves B, Joubert M. Off-label use of u-500 regular insulin with a tubeless automated insulin delivery system in type 1 diabetes and severe insulin resistance: a case report. Diabetes Ther. Published online October 12, 2026. doi:10.1007/s13300-026-01924-x
Relevant Prescribing Information

Limitation of Use [2]
The safety and efficacy of HUMULIN R U-500 used in combination with other insulins has not been determined. The safety and efficacy of HUMULIN R U-500 delivered by continuous subcutaneous infusion has not been determined

Dosage and Administration [2]
Do NOT transfer HUMULIN R U-500 from the HUMULIN R U-500 KwikPen into any syringe.

Warnings and Precautions [2]
Risk Mitigation Strategies for Hypoglycemia
To minimize the risk of hypoglycemia do not administer HUMULIN R U-500 intravenously or in an insulin pump or dilute or mix HUMULIN R U-500 with any other insulin products or solutions

Patient Information [2]
Do not use Humulin R U-500 in an insulin pump or inject Humulin R U-500 into your vein (intravenously)

Relevant Prescribing Information References: [2] Humulin R U-500 (insulin human) injection and Humulin R U-500 KwikPen (insulin human) injection. Prescribing information. Eli Lilly and Company; 2026.
Literature Review

A search of the published medical literature revealed 1 study investigating the researchable question:

Now with the removal of U-500 vials from the market, what is the current guidance, safety literature, and standard of care for U-500 insulin use in the pumps? Is it safe to use a U-500 pen to refill a pump?

Level of evidence

D - Case reports or unreliable data  Read more→



Please see Table 1 for your response.


 

Off-label Use of U-500 Regular Insulin with a Tubeless Automated Insulin Delivery System in Type 1 Diabetes and Severe Insulin Resistance: A Case Report

Design

Case report  

Case presentation

A 46-year-old man with type 1 diabetes, obesity (BMI 33.3 kg/m²), severe insulin resistance, and impaired hypoglycemia awareness (Gold score 6) experienced recurrent hypoglycemia, particularly during overnight work shifts. He had previously transitioned from U-100 to U-500 regular insulin using an Omnipod DASH pump because increasing insulin requirements exceeded the practical capacity of its 200-unit reservoir. His total daily insulin requirement was approximately 245 units (77 units basal and 50–65 units per meal), and he was also receiving metformin 700 mg twice daily.

Due to recurrent hypoglycemia, the patient transitioned to an Omnipod 5 automated insulin delivery system during a 4-day hospitalization while continuing U-500 insulin. Because the pump was designed for U-100 insulin, insulin doses and delivery rates were divided by 5, while insulin-to-carbohydrate ratios and correction factors were multiplied by 5. Initial settings included a maximum basal rate of 1.4 pump-displayed units/hour, maximum bolus of 20 pump-displayed units, insulin-to-carbohydrate ratio of 5 g/unit, correction factor of 60 mg/dL/unit, active insulin duration of 6 hours, and glucose targets of 120 mg/dL during the day and 130 mg/dL overnight. The patient received education on standardized meal announcements, activity mode, and avoiding independent pump-setting adjustments to minimize dosing errors.

At Omnipod 5 initiation, U-500 insulin was supplied in vials. Following vial discontinuation in France in February 2026, the patient received additional training on withdrawing U-500 insulin from pens using syringes supplied with the Omnipod kits. 

Over 12 months, the patient completed five in-person visits and three teleconsultations, with pump settings progressively adjusted based on continuous glucose monitoring (CGM) and pump data to address hypoglycemia and postprandial hyperglycemia. Time in range increased from 75% to 79.1%, while time below range decreased from 9% to 5.7%, with 0.4% of readings below 54 mg/dL. Automated mode was active more than 95% of the time, and the patient reported fewer symptomatic hypoglycemic episodes, although occasional episodes persisted during overnight shifts. No severe hypoglycemia, diabetic ketoacidosis, clinically significant ketosis, or recurrent technical issues suggestive of U-500 insulin incompatibility were reported. A few insulin-leakage events occurred with a subsequently recalled defective pod batch. Total daily insulin requirements increased slightly to approximately 252 units/day. However, outcomes were not separately reported for the period following the transition from U-500 vials to pens, limiting conclusions about pen-to-pump transfer safety.

Study Author Conclusions

In selected people with T1D and severe insulin resistance, carefully supervised off-label use of U-500R with AID may therefore reduce hypoglycemia exposure while preserving patch-pump therapy despite very high insulin requirements. Safe implementation requires unambiguous dose conversion, conservative and individualized settings, structured education, and close review of CGM and pump data. This strategy should be regarded as a pragmatic option when better-matched alternatives are unsuitable, rather than as evidence that U-500R is ideally suited to current AID algorithms.

Table 1 References:
[3] Dreves B, Joubert M. Off-label use of u-500 regular insulin with a tubeless automated insulin delivery system in type 1 diabetes and severe insulin resistance: a case report. Diabetes Ther. Published online October 12, 2026. doi:10.1007/s13300-026-01924-x